What was found
AFT CARGO PIT FLOOR SUPPORT SPLICE CORRODED STA 727 I RBL 8.1. REMOVED DAMAGED SPLICE, FABRICATED SPLICE CHANNEL IAW DWG 146A7506 FIG 2. LOCATED DRILLED AND INSTALLED IAW B737 900 SRM 51 40 2 PG 6 ASA EA 5310 02779.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO PIT FLOOR SUPPORT SPLICE CORRODED STA 727 I RBL 8.1. REMOVED DAMAGED SPLICE, FABRICATED SPLICE CHANNEL IAW DWG 146A7506 FIG 2. LOCATED DRILLED AND INSTALLED IAW B737 900 SRM 51 40 2 PG 6 ASA EA 5310 02779.