What was found
AFT CABIN FLOORBOARD STA 887 TO STA 907 RBL 47 TO RBL 67 IS DELAMINATED. PREPARED DAMAGED AREA APPLIED POTTING COMPOUND BMS 5 28 TYPE 19 AND 4 LAYERS BMS 9 3, FABRIC REPAIR PLY BONDED AREA IAW B737 900 SRM 53 00 50 REP 6 PGS 201 203.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN FLOORBOARD STA 887 TO STA 907 RBL 47 TO RBL 67 IS DELAMINATED. PREPARED DAMAGED AREA APPLIED POTTING COMPOUND BMS 5 28 TYPE 19 AND 4 LAYERS BMS 9 3, FABRIC REPAIR PLY BONDED AREA IAW B737 900 SRM 53 00 50 REP 6 PGS 201 203.