What was found
SIDEWALL SUPPORT INTERCOSTAL CRACKED AT FASTENER HOLE. REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT INTERCOSTAL BETWEEN BS 500J AND 500K IAW SRM 51-40-02 STEP 4B AND C
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SIDEWALL SUPPORT INTERCOSTAL CRACKED AT FASTENER HOLE. REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT INTERCOSTAL BETWEEN BS 500J AND 500K IAW SRM 51-40-02 STEP 4B AND C