What was found
FWD PIT LOWER FLANGE OF FRAME HAS SEVERAL AREAS OF CORROSION AT STA 500F BETWEEN STR 26R 26L. REMOVED DAMAGED SHEAR TIE SECTION OF FRAME, FABRICATED, DRILLED INSTALLED SHEAR TIES IAW B737 400 SRM 53 00 07.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT LOWER FLANGE OF FRAME HAS SEVERAL AREAS OF CORROSION AT STA 500F BETWEEN STR 26R 26L. REMOVED DAMAGED SHEAR TIE SECTION OF FRAME, FABRICATED, DRILLED INSTALLED SHEAR TIES IAW B737 400 SRM 53 00 07.