What was found
AFT PIT FRAME UPPER FLANGE STA 907 DENTED BETWEEN 23L AND 22L BENT. REMOVED FACTORY FRAME AND CUT OUT DAMAGED AREA, FABRICATE, TREATED, PRIMED TOP COATED AND INSTALLED DOUBLER 2 FILLERS AND NEW SPLICE IAW B737 400 SRM 51 70 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT FRAME UPPER FLANGE STA 907 DENTED BETWEEN 23L AND 22L BENT. REMOVED FACTORY FRAME AND CUT OUT DAMAGED AREA, FABRICATE, TREATED, PRIMED TOP COATED AND INSTALLED DOUBLER 2 FILLERS AND NEW SPLICE IAW B737 400 SRM 51 70 11.