What was found
AFT CARGO PIT SILL WEB LOWER SILL BEAM VERTICAL WEB GOUGED BETWEEN STA 800 807 ON O/B SIDE. REMOVED SILL BEAM, RECEIVED NEW PART, LOCATED AND DRILLED HOLES ON NEW PART, INSTALLED LOWER SILL BEAM VERTICAL WEB IAW B737 400 SRM 51 40 05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO PIT SILL WEB LOWER SILL BEAM VERTICAL WEB GOUGED BETWEEN STA 800 807 ON O/B SIDE. REMOVED SILL BEAM, RECEIVED NEW PART, LOCATED AND DRILLED HOLES ON NEW PART, INSTALLED LOWER SILL BEAM VERTICAL WEB IAW B737 400 SRM 51 40 05.