What was found
NR 5 T/E WEDGE IS DELAMINATED 2 INCHES FROM I/B END UPPER SURFACE ON PREVIOUS REPAIR. REPAIRED NR 5 SLAT T/E WEDGE PER SRM 57-43-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 5 T/E WEDGE IS DELAMINATED 2 INCHES FROM I/B END UPPER SURFACE ON PREVIOUS REPAIR. REPAIRED NR 5 SLAT T/E WEDGE PER SRM 57-43-02.