Service difficulty report · Valve · Boeing 737890

Difficulty date
March 28, 2009
Submitted
April 1, 2009
Operation
Air carrier
Aircraft
N579AS
Make and model
Boeing 737890
Aircraft serial
35187
Aircraft time
8,131 hours, 2,379 cycles
Part
Valve
Part number
3989083
Part serial
7709
Condition
Faulted
Location
Cabin Temp
Part time
14,898 hours, 5,060 cycles
Stage of operation
IN
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ZONE TEMP LIGHT ILLUMINATED ON CONT CABIN DURING M/C RECALL. LIGHT EXTINGUISHES WHEN M/C SYSTEM IS RESET. INTERROGATED BOTH NR 1 & NR 2 ZONE TEMP CONTROLLERS PER AMM 21 61 00. ZONE TEMP CONTROLLER NR 1 FAULTED: CONTROL CABIN ZONE TRIM AIR MOD VALVE. REMOVED AND REPLACED TRIM AIR MOD VALVE PER AMM 21 61 21. ETOPS SIG SYSTEM: PART VERIFIED BY SEAMC, 2DN VALVE IN 2 DAYS. BOTH ZONE TEMP CONTROLLERS INTERROGATED. NO FAULTS FOUND. C/B P6 4 ROW B NUMBER C01167 OPENED AND THEN CLOSED AFTER COMPLETION OF WORK (MIG51A 10202). NOTIFIED SEAMC.