What was found
AFT CARGO BAY DOOR SILL AREA HAS CORROSION STA 814 OB OF LIGHTENING HOLES. REMOVED CORROSION 4" X 1.3" X .043" REMAINING THICKNESS OUT OF LIMITS PER SRM 53 60 15. REPLACED PART WITH NEW PART. WORK ACCOMPLISHED PER SRM 51 20 05 51 40 02 51 20 01 AND 53 60 15.