As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND RT ENG START VALVE C/B OPEN P6 2 ROW C COL 4. OPENED/CLOSED NR 2 ENG INBOARD FAN COWL FOR GVI NO SYSTEM DEACTIVATED. INSPECTED CIRCUIT WDM 80 11 11 FOR NR 2 ENG START VALVE C/B. FOUND NORMAL RESET NR 2 ENG START VALVE C/B. NO PRIOR WRITE UPS REF MM 20 60 01. GVI FOUND NO DEFECTS RAN NR 2 ENG OPS GOOD. GROUND VERIFICATION SUCCESSFUL.