What was found
DURING NR 1 ENG IDLE LEAK CHECK FOUND LT VSV ACTUATOR DRIPPING FUEL 20 - 30 DROPS PER MINUTE. REMOVED AND REPLACED NR 1 ENG LT VSV ACT AMM REF 75 31 01. LEAK AND OPS CHECK NORMAL. P/N VERIFIED BY SEAMC. PLT CLEARED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING NR 1 ENG IDLE LEAK CHECK FOUND LT VSV ACTUATOR DRIPPING FUEL 20 - 30 DROPS PER MINUTE. REMOVED AND REPLACED NR 1 ENG LT VSV ACT AMM REF 75 31 01. LEAK AND OPS CHECK NORMAL. P/N VERIFIED BY SEAMC. PLT CLEARED.