What was found
AFTER ENGINE STARTS WHILE PERFORMING AFTER START CHECK LIST ON RECALL ZONE TEMP CONT CAB ILLUMINATED: LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. PERFORMED PROCEDURES AND CALLED MX CONTROL GROUNDED YES. PERFORMED BITE CHECK VERIFIED FAULT ON ZONE TEMP CONT. NR 2 'FLT DECK TRIM AIR VALVE' REMOVED AND REPLACED FLT DECK TRIM AIR VALVE MM 21 61 21. OPS LEAK CHECK GOOD, NO FAULTS NO RECALL ON MASTER CAUTION.