As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLIGHT ATTENDANT REPORTS L1 DOOR HARD TO CLOSE, FWD ENTRY DOOR FAILS THE OPEN TEST REF AMM 52 11 00 755 051 PG 2 PARA 5 [C] ,1 DOOR DOES NOT OPEN AT 600 IN LBS OR LESS [62572]. LUBE DOOR AND ROLLERS AND HINGES REF 52 11 00 705 PGS 1 THRU 8. ALSO TORQUE WAS BELOW 600 [500] TO OPEN, OPS CHECK GOOD MM 52 11 00 755 051 PG 2 ITEM 5 AB AND C.