What was found
AFT CARGO FIRE LIGHT DOES NOT ILLUMINATE DURING TEST. AFT CARGO PIT FIRE DETECTION TEST NORM. PERFORMED TEST NUMEROUS TIMES. REF FIM 26 16 TASK 806, NO HISTORY 90 DAYS, GROUND FUNCTIONAL TESTS PASS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO FIRE LIGHT DOES NOT ILLUMINATE DURING TEST. AFT CARGO PIT FIRE DETECTION TEST NORM. PERFORMED TEST NUMEROUS TIMES. REF FIM 26 16 TASK 806, NO HISTORY 90 DAYS, GROUND FUNCTIONAL TESTS PASS.