What was found
WHILE PERFORMING ETOPS PDC FOUND ELECT LIGHT ON P5 13 MODULE ILLUMINATED. ACCOMPLISHED FIM TASK 24 31 TASK 801. AUX BAT CHGR I STATINV INOP I SPCU INOP I MESSAGES WERE LISTED. PER THIS FIM TASK ALL ARE INTERMITTENT FAULTS. CLEARED FAULTS PER TASK 801 ALL FAULTS CLEARED. ETOPS SIGNIFICANT SYSTEM GROUND VERIFICATION SUCCESSFUL. SEAMC CONTACTED.