Service difficulty report · Valve · Boeing 737890

Difficulty date
May 27, 2010
Submitted
June 2, 2010
Operation
Air carrier
Aircraft
N565AS
Make and model
Boeing 737890
Aircraft serial
35181
Aircraft time
13,527 hours, 4,199 cycles
Part
Valve
Part number
32895625
Part serial
7985
Condition
Failed
Location
Bleed Air Sys
Part time
24,662 hours, 10,848 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 1 LEFT BLEED TRIP OFF LIGHT CAME ON DURING CRUISE AT 400 RESET AND RE-TRIPPED 2 MINUTES LATER AND WOULD NOT RESET. REPLACED PRECOOLER VALVE REF MM 36 12 02 000 400 801. REPLACED HIGH STAGE REGULATOR REF MM 36 11 07 000 400 801. COMPLETED ENG BLEED AIR SYSTEM HEALTH CHECK REF MM 36 11 00 700 801 (17) I(4) ALL CHECKED GOOD. COMPLETED FIM TASK 36 10 00 810 801 REPAIR CONFIRMATION. GROUND VERIFICATION SUCCESSFUL.