Service difficulty report · Sensor · Boeing 737890

Difficulty date
July 6, 2010
Submitted
July 13, 2010
Operation
Air carrier
Aircraft
N587AS
Make and model
Boeing 737890
Aircraft serial
35684
Aircraft time
10,342 hours, 3,008 cycles
Part
Sensor
Part number
MS280341
Condition
Out Of Tolerance
Location
Apu
Stage of operation
TX
How discovered
O
Nature of condition
N
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found