Service difficulty report · Valve · Boeing 737890

Difficulty date
October 20, 2010
Submitted
October 25, 2010
Operation
Air carrier
Aircraft
N565AS
Make and model
Boeing 737890
Aircraft serial
35181
Aircraft time
14,995 hours, 4,656 cycles
Part
Valve
Part number
3989083
Part serial
2757
Condition
Failed
Location
Ac Bay
Part time
39,582 hours, 21,983 cycles
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER ENG START AND BOTH PACKS TURNED ON AND RECALL OF MASTER CAUTION PUSHED "ZONE TEMP" LIGHT ON "CONT CAB" CONTROLLER ILLUMINATED. "MASTER CAUTION PUSH TO RESET" WOULD EXTINGUISH LIGHT. QRH "ZONE TEMP" PROCEDURE RAN AND MAINT (SEA) CONTACTED. REPLACED CONTROL CABIN TRIM VALVE (V143) OPS CHECKED NORMAL & LEAK CHECKED GOOD REF AMM 21 61 21.