As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L2 DOOR BINDS WHILE OPENING AND CLOSING UPPER AND LOWER DOOR ARMS ARE DRAGGING ON CAM PLATES INT MIG2C 277488. FOUND L2 DOOR TORQUE TUBE WORN AND OUT OF LIMITS. RELACED DOOR TORQUE LOWER RADIUS LINK UPPER HINGE LINK AND UPPER CAM PLATE REF 52 13 141 OPS AND PRESSURE CHECKS NORMAL. NO LEAKS NOTED MIG2C 277488.