What was found
FRAME STA 1006 CORRODED UNDER L2 MOP SILL. REMOVED DAMAGED SECTION. FABRICATED HEAT TREATED LOCATED TREATED PRIMED TOPCOATED AND INSTALLED FRAME REPAIR IAW B737 400 SRM 53 00 07 FIG 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME STA 1006 CORRODED UNDER L2 MOP SILL. REMOVED DAMAGED SECTION. FABRICATED HEAT TREATED LOCATED TREATED PRIMED TOPCOATED AND INSTALLED FRAME REPAIR IAW B737 400 SRM 53 00 07 FIG 201.