What was found
R2 (AFT GALLEY SERVICE) DOOR HARD TO CLOSE, ACFT GROUNDED. REPLACED R2 DOOR GUIDE ARM ASSY. IAW AMM 52-41-21-404-004 STEP C1 THRU C5 B. DOOR STILL DIFFICULT TO CLOSE. REMOVED DOOR FROM AIRCRAFT. FOUND THE DOOR MOUNTED TORQUE TUBE TO UPPER SPIGOT CROSSBOLTS WORN ALLOWING THE DOOR TO BECOME MISTIMED AND THE LOWER AND UPPER HINGE ARMS TO MOVE INDEPENDENTLY OF ONE ANOTHER. REPLACED THE BODY MOUNTED TORQUE TUBE RADIUS LINK UPPER/LOWER HINGE LINKS UPPER HINGE LOWER GUIDE PLATE/BEARING LOWER HINGE UPPER STOP PLATE/BEARING DOOR MOUNTED TORQUE TUBE UPPER SLEEVE CROSSBOLTS AND DOOR SNUBBER. REINSTALLED ADJ AND OPS CHECKED R 2 DOOR DOOR OPERATES NORMALLY OK FOR CONTINUED SERVICE.