What was found
WET SOCK SMELL IN CABIN DURING DESCENT INTO PDX BELOW 10 000 SMELL ESPECIALLY STRONG DISSIPATED SLIGHTLY BELOW 6 000 FT. ACCOMP CABIN ODOR T/S PER MM 05 60 00 280 801C1. FOUND APU TO BE SOURCE. OIL FOUND IN DRAIN LINE FOR APU LOAD COMPRESSOR CASE. ACCOMP OIL CONTAMINATION REMOVAL FROM A/C & PNEUMATIC SYSTEMS FOR APU BLEED DUCTING. NO DEFECTS NOTED. ACCOMP APU OPERATIONS TEST PER AMM 49 11 00 710 801. OPS CHECK GOOD.