As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ELECTRIC LIGHT ILLUMINATED AFTER ENGINE START. PER BITE PROCEDURE ELEC LIGHT MESSAGE 24 31 TASK 801 FOUND SPCU TO BE INOP. ACCOMP FAULT ISOLATION OF SPCU PER FIM TASK 24 34 00 810 802 BY CYCLING C/B`S SPCU NORMAL & SPCU STANDBY. REACCOMP BITE PROCEDURE & ELEC LIGHT CLEARED. GROUND VERIFICATION SUCCESSFUL. OKAY FOR CONTINUED SERVICE.