Service difficulty report · Valve · Boeing 737890

Difficulty date
November 30, 2011
Submitted
December 1, 2011
Operation
Air carrier
Aircraft
N584AS
Make and model
Boeing 737890
Aircraft serial
35682
Aircraft time
16,280 hours, 4,985 cycles
Part
Valve
Part number
32144464
Part serial
3060
Condition
Faulty
Location
Bleed Air Sys
Part time
56,990 hours, 32,034 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT BLEED TRIP OFF LIGHT ILLUMINATED. QRH TRIP RESET PROCEDURE SUCCESSFUL. REPLACED NR 1 ENG HIGH STAGE REGULATOR PER MM 36 11 07, NO HELP. ACCOMPLISHED ENG BLEED AIR SYSTEM HEALTH CHECK ON NR 1 ENG PER MM 36 11 00. FOUND HIGH STAGE VALVE BAD. REPLACED NR 1 ENG HIGH STAGE VALVE PER MM 36 11 06. ACCOMPLISHED REPAIR CONFIRMATION PER MM 36 11 00 ENG BLEED AIR SYSTEM HEALTH CHECK GOOD.