What was found
NR 1 ENG ON START AT 31 PERCENT AND NO FUEL FLOW ORC & QRH PROCEDURES ACCOMP. PERFORMED BONDING CKS OF BONDING JUMPER & ACTUATOR REF MM 28 22 11 400 804 FOUND WITHIN LIMITS. REPLACED LT SPAR VALVE ACTUATOR. OPS CHECK NORMAL. A/C OK FOR SERVICE REF AMM 28 22 11 000 804 AND 28 22 11 400 804 OPS AMM 28 22 00 710 801.