Service difficulty report · Valve · Boeing 737890

Difficulty date
June 5, 2011
Submitted
June 7, 2011
Operation
Air carrier
Aircraft
N569AS
Make and model
Boeing 737890
Aircraft serial
35184
Aircraft time
16,139 hours, 5,262 cycles
Part
Valve
Part number
32144464
Part serial
1221C
Condition
Defective
Location
Bleed Air Sys
Part time
10,307 hours, 4,169 cycles
Stage of operation
DE
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEAVING FL390 AS THROTTLES BEGAN TO COME BACK FOR DESCENT AMBER "BLEED TRIP OFF" LIGHT FOR RIGHT SIDE ILLUMINATED. QRH PROCEDURES WERE RUN. LIGHT EXTINGUISHED WHEN RESET PUSHED. NOTE WING ANTI ICE WAS NOT IN USE AT ANY TIME. ALSO NO ENG DE ICE ON. DURING "TRIP" OBSERVED PRESSURE CHANGES IN CABIN. ACCOMPLISHED HSV INSPECTION PER FIM 36 10 00 810 801. FOUND VALVE TO HAVE SLIGHT ROUGH DRY FEELING REPLACED PRECAUTIONARY PER MM 36 11 06 400 801. REPLACED BAR LEAK CHECK GOOD. COMPLETED TEST OF BAR AND HSV PER FIM 36 10 00 810 801 STEP G PARA 1 2 3. NO DEFECTS NOTED. REPLACED NR 2 ENG HARNESS MW0311 REF MM 73 21 06. ACCOMPLISHED WIRE HARNESS MW0311 OPS MM 73 21 06 F(D)(3). REPLACED PRECOOLER CONTROL VALVE, OPS CHECK AND LEAK CHECK GOOD REF MM 36 12 02.