Service difficulty report · Shutoff Valve · Boeing 737890

Difficulty date
June 10, 2011
Submitted
June 14, 2011
Operation
Air carrier
Aircraft
N597AS
Make and model
Boeing 737890
Aircraft serial
35689
Aircraft time
11,796 hours, 3,832 cycles
Part
Shutoff Valve
Part number
32145525
Part serial
10639
Condition
Failed
Location
Bleed Air Sys
Part time
11,796 hours, 3,832 cycles
Stage of operation
IN
How discovered
C
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PERFORMED NR 2 ENGINE BLEED AIR HEALTH CHECK. PRSOV AND HIGH STAGE VALVE FAILED. NR 2 PRSOV REPLACED AND INSTALLATION TEST GOOD IAW B737NG MM 36 11 04. NR 2 HIGH STAGE VALVE REPLACED AND INSTALLATION TEST GOOD IAW B737NG MM 36 11 08.