As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND GOUGED DENT 9" FWD OF AFT CARGO DOOR BELOW STRINGER S21R. DENT MEASURES 1.6 X 1.7" MAX DEPTH .070". GOUGE IN DENT MEASURES .9" X .1" MAX DEPTH .015". VERIFIED DAMAGED AREA LOCATED AT 2" BELOW S22R AND FUS STA 789 IAW SRM 53 00 00 GENERAL FUS STA DIAGRAM FIG 1. REPAIRED DAMAGE FWD OF AFT CARGO DOOR. REF EA 700 53EA 06362.