As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NUMBER TWO (2) ENGINE GENERATOR INOPERATIVE. NR 2 GCU SHOWS IDG FAULT. ACCOMPLISHED NR 2 GCU BITE PER FIM 24 21 TASK 801. NO FAULTS NOTED. FOUND NR 2 IDG OVERSERVICED. SERVICED PER MM 12 13 21. RAN ENGINE NO HELP. REPLACED NR 2 ENGINE IDG ASSY REF M/M 24 11 11 SYSTEM OPS CHECKS NORMAL REF M/M 24 11 00 700 803.