What was found
RIGHT PACK COMES ON WHEN RECALL IS PUSHED GOES OUT WHEN RESET IS PUSHED. PERFORMED BITE CHECK ON NR 1 & NR 2 PACK ZONE TEMP CONTROLLERS PER FIM TASK 21 62 00 810 801 NR 2 PACK ZONE CONTROLLER HAD A PACK SENSOR FAULT RESET FAULT PER SAME REFERENCE. PERFORMED BITE CHECK ON NR 2 CONTROLLER OPS CHECK GOOD. NO FAULTS NOTED.