As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT PACK LIGHT ILLUMINATES ON RECALL. R PACK/ZONE TEMP CONTROLLER BITE TEST PER FIM 21 62 00 810 801 SHOWED R RAM AIR ACTUATOR FAULT. REPLACED RIGHT RAM AIR ACTUATOR PER MM 21 51 21 000 801 / MM 21 51 21 400 801 OPS NORMAL. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST PER MM 21 61 00 700 806 002 ALL TESTS PASS.