What was found
ON CLIMBOUT, STAB TRIM BECAME INOPERATIVE ON RUNNING QRH PROCEDURE FOUND STAB TRIM CONTROL CIRCUIT BREAKER POPPED. DIVERSION TIME: 28 MINUTES. DISCONNECTED ELECTRONIC CONNECTOR CAPT CONTROL CUTOUT SWITCH. CIRCUIT BREAKER REMAINS CLOSED WITH ELECTRONIC STAB MOVEMENT. R & R CAPTAIN`S CONTROL COLLUMN SWITCH IAW 27-41-51-400-801. OPS CHECK OF CAPTS COLUMN CUTOUT SWITCH IAW 27-41-710-801. SATISFACTORY STAB TRIM MOTOR TEST IAW AMM 27-41-71-700-801. STAB TRIM MOTOR TEST 22-11-601-701-801, PERFOMED SATISFACTORY. STAB TRIM CONTROL CIRCUIT BREAKER REMAINS CLOSED THROUGHOUT TEST.