Service difficulty report · Shutoff Valve · Boeing 737890

Difficulty date
April 24, 2012
Submitted
April 27, 2012
Operation
Air carrier
Aircraft
N506AS
Make and model
Boeing 737890
Aircraft serial
35690
Aircraft time
14,656 hours, 4,749 cycles
Engine
Cfmint CFM567B27
Part
Shutoff Valve
Part number
32145526
Part serial
2297C
Condition
Failed
Location
Nr 2 Engine
Part time
36,272 hours, 16,804 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

JUST AFTER TAKEOFF, RT BLEED TRIP OFF LIGHT ILLUMINATED ANTI ICE OFF NORMAL BLEED CONFIGURATION. OUT OF 2000 FT TRIP RESET WAS PUSHED AND BLEED TRIP OFF LIGHT EXTINGUISHED RT DUCT PRESSURE WAS RE-ESTABLISHED AND DUCT PRESSURE WAS ABOUT EQUAL. DURING CLIMB, RT PRESSURE BEGAN TO DROP LEVEL AT FL 360 LT 42 PSI RT 25 PSI. SPLIT REMAINED CONSTANT FOR ABOUT 2 HRS 20 MINUTES THEN RT PRESSURE INCREASED TO 38 PSI, LT 43 PSI. PRESSURE REMAINED AT THOSE VALUES FOR REST OF CRUISE FLIGHT. FOUND NR 2 ENGINE PRSOV LEAKING. REPLACED IAW AMM 36-11-04. ALSO, REPLACED PRECOOLER CONTROL VALVE IAW AM 36-12-02 AS A PRECAUTIONARY MEASURE. PERFORMED HIGH POWER RUN NO DEFECTS NOTED. OPS CHECK NORMAL. OK FOR SERVICE.