What was found
AFTER RUNNING APU FOR 15 MIN, FUEL QTY DROPPED 800 LBS. ACFT GROUNDED. COMPARISON CHECK PERFORMED REF MM 28-41-00, OPS NORMAL. ALL TANKS WITHIN ALLOWABLE LIMITS. PERFORMED FIM 28-41, TASK 814, OPS NORMAL. NO FAULTS. SIGNIFICANT ETOPS SYS GROUND VERIFICATION, OPS NORMAL.