What was found
CABIN FLOORBEAM TEE CORRODED BS 947.5 RBL 52. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. REPAIRED FLOORBEAM IAW SRM 53-70-51 REPAIR 5 FIG 205 PAGE 213.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM TEE CORRODED BS 947.5 RBL 52. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. REPAIRED FLOORBEAM IAW SRM 53-70-51 REPAIR 5 FIG 205 PAGE 213.