What was found
AFT CARGO DOOR CUTOUT LOWER WEB S 792 TO 849 S25R, RBL 35 HAS AREAS OF CORROSION. WEB FOUND TO BE OUT OF LIMIT IAW SRM 53-60-15. LOCATED DRILLED DEBURRED NEW WEB IAW SRM 51-40-05. INSTALLED NEW WEB IAW SRM 51-40-02 AND DWG 146A8340.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO DOOR CUTOUT LOWER WEB S 792 TO 849 S25R, RBL 35 HAS AREAS OF CORROSION. WEB FOUND TO BE OUT OF LIMIT IAW SRM 53-60-15. LOCATED DRILLED DEBURRED NEW WEB IAW SRM 51-40-05. INSTALLED NEW WEB IAW SRM 51-40-02 AND DWG 146A8340.