What was found
MAIN CABIN AFT FLOORBEAM TEE CORRODED BS 951, RBL 10. FOUND TO BE OUT OF LIMITS. REMOVED DAMAGE IAW SRM 53-70-51, RIG 205, REPAIR 5. PERFORMED HFEC IAW NDT MANUAL 651-00-00, FIG 23 USING T8257A ON FWD AND AFT CUTOUT. NO CRACKS. FORMED REPAIR ANGLES IAW SRM 53-70-51, FIG 205, REPAIR 5. HEAT TREATED REPAIR ANGLES TO T6. FABRICATED TEE ANGLES, STRAPS, AND FILLERS IAW SRM 53-70-51, REPAIR 5. ALODINED PRIMED AND TOP COATED REPAIR PARTS IAW SRM 51-20-01. INSTALLED TEE REPAIR IAW SRM 53-70-51, FIG 205, REPAIR 5.