What was found
DETECTOR FAULT LIGHT ILLUMINATES DURING CARGO FIRE TEST, AFT LIGHT REMAINS EXTINGUISHED. R & R AFT A3 AFT CARGO SMOKE DETECTOR. OPS NORMAL, REF 26-16-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DETECTOR FAULT LIGHT ILLUMINATES DURING CARGO FIRE TEST, AFT LIGHT REMAINS EXTINGUISHED. R & R AFT A3 AFT CARGO SMOKE DETECTOR. OPS NORMAL, REF 26-16-01.