What was found
RIGHT PACK ILLUMINATED DURING MASTER CAUTION RECALL. THE LIGHT EXTINGUISHED WHEN MASTER CAUTION SYS IS RESET. ACCOMPLISHED BITE TEST ON THE TEMP CONTROLLERS. FOUND NR 2 PACK THIS TEMP CONTROL VALVE LIGHT ON . RESET NR 2 CONTROLLER. SYS GROUND VERIFIED GOOD REF MM TASK 21-61-00-700-806-002. NO PACK LIGHT ON ON RECALL.