As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 1 ENGINE FAN DUCT PANELS AT 100, 300, 500 AND 1100 LOCATIONS HAVE PULLED THROUGH BOLTS, LOOSE BOLTS (2 LOC) AND LOOSE PANEL RESPECTIVELY. ACFT GROUNDED. TIGHTENED PANELS AT 100, 300 & 500. REPLACED PANEL AT 1100 IAW AMM 72-23-07-000-801-F00.