What was found
CORROSION FOUND IN FWD CARGO BAY ON STRAP COMMON TO FRAME AT FS 492 AFT SIDE OF DOOR OPENING. ACFT GROUNDED. CORROSION BLENDED OUT AND REMOVED REF SRM 53-30-15, AD-1, PG 105. DEPTH OF DAMAGE WAS .037 OUT OF LIMITS IAW SAID REF REMOVED STRAP. SEVERAL HOLES FOUND TO BE ELONGATED IN TURTLE STRAP. REMOVED TURTLE STRAP. STARTING FABRICATION IAW DWG 65-59659. INSPECTION VERIFIED MATERIAL ID 7075-T6, .080 THICK. REMOVED WEB FOR S/M ACCESS. ACCOMPLISHED HFEC TO FASTENER HOLES REF. BNDT 51-00-00 PART 6, FIG 16, NO CRACKS NOTED. REMOVED RT SIDEWALL LINER AFT OF CARGO DOOR FOR ACCESS WITH REF TO AMM 25-52-73-004-018. CUT FILLER STRAP UNDER FRAME AND REMOVED IAW ENGINEERING REQUEST. REAMED ELONGATED HOLES IN FRAME IAW ENG REQUEST. INSTALLED OF REPAIR COMPLETED, REF EA 400-53EA-08690. ACCOMP PERM REPAIR AT NEXT HMV ON DEFERRAL.