What was found
FRAME AT BS 500B HAS A CRACK AT 1.04 WIRE PENETRATION HOLE 900 POS AS VIEWED LOOKING AFT EXTENDING INWARD APROX .1250 LONG. ACFT GROUNDED. REPAIRED FRAME IAW SRM 53-00-07, REP 13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME AT BS 500B HAS A CRACK AT 1.04 WIRE PENETRATION HOLE 900 POS AS VIEWED LOOKING AFT EXTENDING INWARD APROX .1250 LONG. ACFT GROUNDED. REPAIRED FRAME IAW SRM 53-00-07, REP 13.