What was found
RT SHEAR WEB R2 DOOR AFT WEB UNDER MOPSILL CORRODED ON LOWER SURFACE. ACFT GROUNDED. BLENDED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-60-15, FIG 101. R & R WEB IAW SRM 51 40 02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT SHEAR WEB R2 DOOR AFT WEB UNDER MOPSILL CORRODED ON LOWER SURFACE. ACFT GROUNDED. BLENDED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-60-15, FIG 101. R & R WEB IAW SRM 51 40 02.