What was found
FWD CARGO BAY, BS 500I AFT BULKHEAD, FLOOR SUPPORT STRUCTURE RBL 22 CORRODED. FLOOR SUPPORT CORRODED OUT OF LIMITS IAW SRM 51-10-02. LOCATED DRILLED, COUNTER SUNK AND DEBURRED IAW SRM 51-40-05. INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY, BS 500I AFT BULKHEAD, FLOOR SUPPORT STRUCTURE RBL 22 CORRODED. FLOOR SUPPORT CORRODED OUT OF LIMITS IAW SRM 51-10-02. LOCATED DRILLED, COUNTER SUNK AND DEBURRED IAW SRM 51-40-05. INSTALLED IAW SRM 51-40-02.