ZONE TEMP LIGHT ILLUMINATES ON RECALL, EXTINGUISHES WITH MASTER CAUTION RESET IAW QRH. COULD NOT DUPLICATE. ACCOMP FIM 21-62/842. NR 1 & 2 TEMP CONTROLLER BITE, FLT, & VERIFY ALL GO, NO FAULTS LOGGED. OPERATED LT PACK FOR SEVERAL MIN ZONE TEMP LT DID NOT COME BACK. GROUND VERIFICATION OF PRIMARY TEMP CONT OPS CK NORMAL.