As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON TOUCHDOWN SPAR VALVE CLOSED LIGHT ILLUMINATED AFTER 5-6 SECONDS LIGHT EXTINGUISHED. NO ABNORMAL INDICATIONS. VERIFIED WITH CREW NR 1 SPAR VALVE WAS THE AFFECTIVE UNIT. R & R NR 1 SPAR VALVE IAW AMM 28-22-11-400-804. OPS CHECK OK IAW AMM 28-22-10-710-801.