What was found
MAIN CABIN, FLOOR STRUCTURE CORRODED ON TOP AT BS 322, LBL. 12. GROUNDED. REMOVED FLOOR PANEL IAW SRM 51-40-02. LOCATED AND DRILLED NEW FLOOR PANEL IAW SRM 51-40-02 AND DWG 141A5410. REV -. INSTALLED NEW FLOOR PANEL IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN, FLOOR STRUCTURE CORRODED ON TOP AT BS 322, LBL. 12. GROUNDED. REMOVED FLOOR PANEL IAW SRM 51-40-02. LOCATED AND DRILLED NEW FLOOR PANEL IAW SRM 51-40-02 AND DWG 141A5410. REV -. INSTALLED NEW FLOOR PANEL IAW SRM 51-40-02.