What was found
AFT PIT, TWO GUSSETS ATTACHED TO 727D FRAME CRACKED. REMOVED GUSSETS. FABRICATED NEW IAW B DWG 65-65710 AND SRM 51-40-05, FIG 2. INSTALLED NEW GUSSETS IAW SRM 51 40 02, P66, PAR D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, TWO GUSSETS ATTACHED TO 727D FRAME CRACKED. REMOVED GUSSETS. FABRICATED NEW IAW B DWG 65-65710 AND SRM 51-40-05, FIG 2. INSTALLED NEW GUSSETS IAW SRM 51 40 02, P66, PAR D.