What was found
WITH PRESSURE CONTROL IN AUTO, AUTO FAIL LIGHT ON WITH GREEN ALT LIGHT ON, MOVING SWITCH TO ALT, AUTO FAIL LIGHT IS NOT ILLUMINATED BUT GREEN ALT LIGHT STAYS ON - DONE WITH QRH. RESET AUTO FAIL LIGHT & BITE TEST BOTH CABIN PRESSURE CONTROLLERS, NO FAULT LOGGED. GROUND TEST OPS CHECKED NORMAL REF AMM 21-31-00.