Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
January 21, 2013
Submitted
January 24, 2013
Operation
Air carrier
Aircraft
N594AS
Make and model
Boeing 737890
Aircraft serial
35191
Aircraft time
18,616 hours, 5,774 cycles
Part
Modulating Valve
Part number
3989083
Part serial
8322
Condition
Failed
Location
Rt Pack
Part time
20,871 hours, 7,607 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT PACK FAILED IN FLIGHT. ACFT GROUNDED. BITE TEST OF NR 2 ZONE TEMP CONTROLLER HAS FAULT TCV THIS PACK. REPLACED RT TCV IAW AMM 21-51-10-000-400-801. BUBBLE TEST REVEALED NO AIR LEAKS. RT PACK TEMP CONTROLLER BITE NORMAL - NO CURRENT FAULTS REF 21-61-00. PERFORMED OPS CK IAW TASK 21-61-00-700-807-002, OPS GOOD.